Skip to content
Back to Portfolio
ProValve Design - Biomechanical prosthetic heart valve simulation

ProValve Design

ML-driven generative design framework for prosthetic heart valves

Client: Kemerovo Cardiology Center · Kemerovo · Russia 🇷🇺
AutoMLPythonOptunascikit-learnSHAPAbaqus

Highlights

Situation

The Kemerovo Cardiology Center needed a faster, data-driven method to prototype prosthetic heart valves, as traditional CAD/FEM approaches were time-intensive.

Task

Build an ML-optimization pipeline to streamline valve design and explore a vast design space efficiently.

Action

Trained ML models on 11,500+ FEM-evaluated geometries and integrated six optimization algorithms to identify high-performance designs.

Result

Achieved 95% design efficacy, >96% model accuracy (R²), and significantly reduced prototyping time for clinically viable valves.

Core Team

Viacheslav Danilov

Viacheslav Danilov

Lead Data Scientist

Politecnico di Milano

Milan · Italy 🇮🇹

Kirill Klyshnikov

Kirill Klyshnikov

Biomedical Scientist

Kemerovo Cardiology Center

Kemerovo · Russia 🇷🇺

Farid Melgani

Farid Melgani

Professor

University of Trento

Trento · Italy 🇮🇹

Pavel Onishchenko

Pavel Onishchenko

Research Scientist

Kemerovo Cardiology Center

Kemerovo · Russia 🇷🇺

Evgeny Ovcharenko

Evgeny Ovcharenko

Biomedical Engineer

Kemerovo Cardiology Center

Kemerovo · Russia 🇷🇺

Overview

Valvular heart disease affects millions globally, and prosthetic heart valves (PHVs) are a primary intervention. Traditional methods for PHV design, such as computer-aided design (CAD) and finite element analysis (FEM), are time-intensive and limited in exploring large design spaces.

This project introduces a generative design framework that integrates machine learning models and optimization algorithms to accelerate and improve PHV design. The framework achieves 95% design efficacy, significantly reducing error rates and enabling the generation of new valve geometries tailored to clinical and manufacturing constraints.

Data

The dataset comprised 11,565 prosthetic heart valve designs, each generated using a parametric model with six critical parameters:

  • •Parameters: Height (HGT), diameter (DIA), leaflet thickness (THK), curvature (CVT), elevation angle (ANG), and material stiffness (ELM).
  • •Simulations: FEM simulations were performed for each design to evaluate mechanical performance under physiological conditions.
  • •Output Metrics: Leaflet opening area (LMN) and peak stress (STS), critical indicators of PHV functionality and durability.

The valve structure and parametric model are illustrated in Figure 1.

Figure 1. Prosthetic heart valve structure showing the parametric model with six critical design parameters.

Methods

The methodology integrates machine learning and optimization algorithms to enable efficient exploration of the design space:

  • Parametric Modeling and Simulation: PHV geometries were generated algorithmically using a MATLAB-based parametric model, then analyzed using FEM to simulate mechanical performance under physiological conditions.
  • Machine Learning Model Training: Using the dataset of 11,565 FEM-evaluated designs, we trained regression models including Random Forest, LightGBM, and ensemble methods. Models predicted LMN and STS with R² > 96%.
  • Optimization Algorithms: Six state-of-the-art algorithms were deployed: Random Search (RS), Tree-structured Parzen Estimator (TPE), CMA-ES (CMA), NSGA-II, MOTPE, and Quasi-Monte Carlo (QMC).
  • Hybrid Approach: By combining ML predictions with optimization algorithms, we accelerated the search for optimal designs while reducing reliance on computationally expensive FEM simulations.

The complete generative design workflow integrating parametric modeling, ML predictions, and optimization is shown in Figure 2.

Figure 2. Generative design workflow showing the integration of parametric modeling, machine learning, and optimization algorithms.

Results

The proposed framework demonstrated significant improvements in PHV design efficiency:

  • Model Accuracy: Trained ML models achieved R² values exceeding 96% with MAPE of 11.8% and 10.2% for opening area and peak stress.
  • Design Efficacy: TPE and NSGA-II achieved efficacy scores exceeding 95%, identifying superior designs in fewer iterations.
  • Parameter Trends: Algorithms favored thinner leaflets and larger diameters, contributing to higher opening areas while maintaining acceptable stress levels.

Examples of optimized valve designs in the open state are shown in Figure 3, showcasing improvements over the initial geometry.

Figure 3. Examples of optimized valve designs generated by different optimization algorithms, showing variations in opening area and stress distribution.

The videos below demonstrate the valve opening behavior for designs generated by the following optimization algorithms:

Random Search
Tree-structured Parzen Estimator

Conclusion

This generative design framework demonstrates the transformative potential of combining machine learning and optimization for medical device development. It enables faster, more efficient design iterations, significantly reducing the time and cost of prototyping.

Future work will expand this approach to incorporate advanced material modeling and fluid-structure interactions, further refining prosthetic heart valve designs for improved patient outcomes.

Keep Exploring

Medical Devices

Non-invasive ICP monitoring using deep learning on cerebral blood flow signals from near-infrared photonic sensors.

December 2025
Image-Guided Surgery

Deep learning solution for surgical tool segmentation in 3D ultrasound, achieving 93.6% Dice score for real-time catheter localization.

February 2023